Which Company are you working for?Sturdie Trade Services
Which Trade are you working for?Electrical
StateNEW ZEALAND
Technician's NameGino Kea
Sturdie Job Number56465
Date of Visit23/04/2021
Swarovski Site in New Zealandqueen_st
Location NameQueen St
Select AuditPlatinum
SF44 General Lighting & Power
SF44 GENERAL LIGHTING & POWER
Are there accurate switchboard legends within each switchboard?No - please add details in “Electrical List of Repairs”
Switchboard is clear from obstructions with no signs of damageYes
Switched Socket Outlets
  • Carry out visual check on SSOs for signs of misuse, blackening or deterioration
  • Check and report any outlets with multiple power boards overloading
  • Ensure any power boards used have an integral over-current limiter
Furniture / Cabinet Lighting Checklist
  • Check correct operation of all luminaries
  • Repair / report on any faulty luminaries/control gear
  • Provide costing to repair/replace
Window Display Boxes - Is the Cabling in good conditions?Yes
Window Display Boxes - Is the Socket in good conditions?Yes
TimersCheck timers for correct operation and timing
Lighting operational, (example: logo, ceiling lighting)?No, please comment below and add repair details in “Electrical List of Repairs”
Comments

1x downlight is not illuminated. 8x 30W lamps are not illuminated.

Paint & surfaces are clean?Yes
Locks work on all fixtures?No, please comment below and add repair details in “Electrical List of Repairs”
Comments

4x drawers are not locking.

Joinery in good condition free from damage, chips, dents or defects?Yes
Skirting in good condition?No, please comment below and add repair details in “General List of Repairs”
Comments

Some skirting is coming away from the wall at the front entrance.

General cleanliness of fixtures, ceilings, P.O.S - provide detailsGood
General cleanliness of Façade? provide detailsGood
Windows visual and functional check, adjustments required?Yes, please comment below and add repair details in “General List of Repairs”
Door handles clean and tight?Yes
Bi-fold Doors / Roller Shutters in good working condition and clean?Yes
Flooring
  • Check if any sealing of joints is required.
  • Check for any trip hazards in the sales and backroom areas
  • Check any painted lines are clean and visible
PlumbingCheck all sanitary facilities for damaged parts, leaking fittings, and blockages
Test and TagInspection of mobile and stationary electrical appliances are all within date.
Is the Emergency Exit (Egress path) clear?Yes
General List of Repairs and additional works required – photo’s of faults are required
Defect Item Location of Item Details of Problem Repaired on Site Quote to be Sent Comments
4x drawers Shop floor Not locking N N Locksmith required. John to raise work order if repairs are required
Downlight Shop floor Not illuminated N N To be completed on tracking #178111650
Skirting Front entrance Coming away from wall N N Shopfitter required. John to raise work order if repairs are required
30W lamps Shop floor Not illuminated Y N Replaced lamps on tracking# 180127607
General List Photos
  • General List Photos
  • General List Photos
  • General List Photos
  • General List Photos
  • General List Photos
  • General List Photos
  • General List Photos
  • General List Photos
  • General List Photos
  • General List Photos
Photographs taken of items requiring further repairs.Yes
Are there any Warranty items needing to be repaired?No
Next Test Due in 1 months21/05/2021
Technician's NameGino Kea
Store Manager's NameHoman Chung