Which Company are you working for?Sturdie Trade Services
Which Trade are you working for?Electrical
StateVIC
Technician's NameNathan McBain
Sturdie Job Number62433
Date of Visit20/04/2022
Swarovski Site in VICemporium_melbourne
Location NameEmporium Melbourne
Select AuditPlatinum
SF44 General Lighting & Power
SF44 GENERAL LIGHTING & POWER
Are there accurate switchboard legends within each switchboard?Yes - please upload a photo of the plan/ send to maintenance@sturdie.com.au
If Yes, please upload all copies of legends here... (Limit of 6 megabytes total)If Yes, please upload all copies of legends here... (Limit of 6 megabytes total)
Switchboard is clear from obstructions with no signs of damageYes
Switched Socket Outlets
  • Carry out visual check on SSOs for signs of misuse, blackening or deterioration
  • Check and report any outlets with multiple power boards overloading
  • Ensure any power boards used have an integral over-current limiter
Furniture / Cabinet Lighting Checklist
  • Check correct operation of all luminaries
  • Repair / report on any faulty luminaries/control gear
  • Provide costing to repair/replace
Window Display Boxes - Is the Cabling in good conditions?Yes
Window Display Boxes - Is the Socket in good conditions?Yes
TimersCheck timers for correct operation and timing
Lighting operational, (example: logo, ceiling lighting)?No, please comment below and add repair details in “Electrical List of Repairs”
Comments

-10 × Recessed square ceiling lights failed to illuminate

-"V" and "Swan Logo" of front entrance logo failed to illuminate

Paint & surfaces are clean?No, please comment below and add repair details in “Electrical List of Repairs”
Comments

- Crack in ceiling plaster between A/C vent and wall LHS shop near front

Locks work on all fixtures?Yes
Joinery in good condition free from damage, chips, dents or defects?Yes
Skirting in good condition?Yes
General cleanliness of fixtures, ceilings, P.O.S - provide detailsGood
General cleanliness of Façade? provide detailsGood
Windows visual and functional check, adjustments required?No
Door handles clean and tight?Yes
Bi-fold Doors / Roller Shutters in good working condition and clean?Yes
Flooring
  • Check if any sealing of joints is required.
  • Check for any trip hazards in the sales and backroom areas
  • Check any painted lines are clean and visible
Comments

1 × GROUT JOIN IN TILES MISSING/LOOSE . LENGTH OF STORE

PlumbingCheck all sanitary facilities for damaged parts, leaking fittings, and blockages
Comments

N/A

Test and TagInspection of mobile and stationary electrical appliances are all within date.
Is the Emergency Exit (Egress path) clear?Yes
General List of Repairs and additional works required – photo’s of faults are required
Defect Item Location of Item Details of Problem Repaired on Site Quote to be Sent Comments
Square Recessed Ceiling Light Shop Floor Failed to illuminate N Y Quote to be sent for approval
"V" and "Swan logo" Front Entrance Failed to illuminate N TBA Please advise if quote is required
Grout Join Length of Store Grout loose or missing N TBA Please advise if quote is required
General List Photos
  • General List Photos
  • General List Photos
  • General List Photos
  • General List Photos
  • General List Photos
Photographs taken of items requiring further repairs.Yes
Are there any Warranty items needing to be repaired?No
Next Test Due in 1 months20/05/2022
Site Status SelectorStore now fully compliant
Technician's NameNATHAN MCBAIN
Store Manager's NameDahong Hu