| Which Company are you working for? | Built Electrical |
|---|
| Which Trade are you working for? | Electrical |
|---|
| State | NSW |
|---|
| Date of Visit | 14/02/2018 |
|---|
| Technician's Name | Matthew Mullins |
|---|
| Built Job Number | 28084 |
|---|
| Swarovski Site in NSW | myer_sydney |
|---|
| Test Period | 12 Monthly (90 minutes) |
|---|
| Exit/Emergency Light Checklist | - Check there has been no power interruption for at least 16 hours prior to test
- Carry out discharge test to ensure the luminaries remain illuminated for the required in service duration (90 or 120 minutes)
- Re-instate power to luminaries and check that the battery charge operation indicatior functions correctly
- Report any failures and provide costing to rectify (where applicable)
|
|---|
| Timers | - Check timers for correct operation and timing
|
|---|
| General Checklist | - Check correct operation of all luminaries
- Report on any faulty luminaries/control gear
- Provide costing to repair/replace
|
|---|
| Are there accurate switchboard legends within each switchboard? Please take a photo send with report to epm@builtelectrical.com.au | No |
|---|
| Switched Socket Outlets | - Carry out visual check on SSOs for signs of misuse, blackening or deterioration
- Check and report any outlets with multiple power boards overloading
- Ensure any power boards used have an integral over-current limiter
|
|---|
| Are there any Warranty items needing to be repaired? | No |
|---|
| ELECTRICAL LIST OF REPAIRS & ADDITIONAL WORKS REQUIRED - (ALL FIELDS MANDATORY) - Please supply photo's | | Defect Item |
Location of Item (on premises) |
Quantity |
Details of fault /problem |
Repaired on Site? (YorN) |
Quote to be sent? (YorN) |
To return to Site |
Comments |
| Display cabinets small LED spot lights |
Display |
10+ |
Individual lights not working within a strip of lights |
N |
N |
N |
John, please confirm if repairs are required |
| Vertical strip LED in corners of display cabinets |
Vitrine display |
10+ |
Individual lights not working within a strip of lights |
N |
N |
N |
John, please confirm if repairs are required |
|
|---|
| General Works Checklist | - Inspect all furniture and fittings for visible damage
- Inspect all walls, ceilings, skirtings and floors for visible damage
- Inspect storefront, façade and store LED logo for correct operations and visible damage
- Check fire extinguishers, update compliance tags/labels
|
|---|
| Are there any repairs and additional works required? | Yes |
|---|
| General List of Repairs and additional works required | | Defect Item |
Location of Item |
Details of Problem |
Repaired on Site |
Quote to be Sent |
Comments |
| Cabinet lock |
Cabinet closest to staff door |
Broken lock |
N |
N |
John, please confirm if repairs are required |
| Cabinet lock |
Various cabinets and drawers in store |
Lock is loose in mounting location |
N |
N |
John, please confirm if repairs are required |
| Glass display case |
Customer side of vitrine display close to building column |
Glue has come unstuck and corner doesn't line up |
N |
N |
John, please confirm if repairs are required |
| Fire Extinguisher |
Store |
Not Required |
N |
N |
Not in Swarovski area, however Myer would have these around their store |
|
|---|
| Next Test Due in 3 months | 14/05/2018 |
|---|
| Site Status Selector | Store now fully compliant |
|---|
| Technician's Name | Matthew Mullins |
|---|
| Store Manager's Name | Katy Chang |
|---|
| |
|---|
| |